HP RAID Server Data Recovery.

0871 977 2999

RAID Server + NAS.

Contact

Emergency Diag, Rebuild, Recovery.

Click Below for:-

HQ and Regional Office Addresses

HP RAID Server Data Recovery.

Datlabs are expert in the repair, rebuild and recovery of data from all variants of HP RAID configured servers. Our R&D program has produced proprietary solutions such as RAID Scope that keep Datlabs at the forefront of this demanding area of the data recovery industry. Serving our customers where RAID equipment manufacturer help and support is not effective in satisfying the imperatives of their business. We support large organisations and small to medium enterprise in getting their Server facilities up and running. We have offices throughout the country London, Manchester Birmingham, Leeds and Glasgow and maintain points of presence in other major city locations.

HP RAID Server Recovered by Datlabs.

  • HP DL Rackmount
  • HP DL60
    HP DL80
    HP DL120
    HP DL160
    HP DL180
    HP DL320
    HP DL360
    HP DL380’s
    HP DL560
    HP DL580’s
    HP DL980
  • HP ML Tower
  • HP ML10
    HP ML150
    HP ML310
    HP ML350
    HP ML350
    HP ML350
  • HP BL Blade
  • HP BL460
    HP BL465c
    HP BL620
    HP BL660
    HP BL680
    HP BL685
  • HP SL Scalable
  • HP SL230
    HP SL2500
    HP SL250s
    HP SL270s
    HP SL4540
    HP SL6500
  • HP ProLiant XL
  • HP Proliant XL220
    HP Proliant XL230
    HP Proliant XL730
    HP Proliant XL740

We rebuild ALL Corrupt File Systems.

Datlabs also rebuild and recover data from HP storage systems such as HP StorageWorks, HP 3PAR StoreServ and HP StoreAll

  • Windows (NTFS, ReFS, FAT, exFAT)
    Mac (HFS, HFS+/J/X)
    Linux (EXT2/3/4)
    Unix UFS
    VM-Ware (VMFS) / ESXi
    Guardian
  • SFS
    XFS
    ZFS including RAID pools
    FAT12/16/32
    BTRFS
    Reiser FS

HP SmartDrive.

The HP SmartDrive application for the HP ProLiant servers have a fault and activity indicator microcontroller whos function is monitor, store and report data concerning the operation and status. of the physical hard disk drives in the RAID Array. The SmartDrive application also ensures that only genuine HP hard drives are available to the array. The drive’s front bezel includes a blue backlight for locating a specific SmartDrive selected from within the storage software. An icon-based display reports the drive’s status. A do-not-remove LED helps prevent a drive failure whenever anyone tries to remove the wrong drive. Other serviceability improvements include authentication, failure logging, and integration with the HP Active Health System.

HP RAID Configuration.

You can discover more information concerning configuring a HP RAID Server here in our data recovery articles section.

HP RAID Hard Drive Failures.

When a drive fails, all logical drives that are in the same array are affected. Each logical drive in an array might be using a different fault-tolerance method, so each logical drive can be affected differently.

  • RAID 0 configurations do not tolerate drive failure. If any physical drive in the array fails, all RAID 0 logical drives in the same array also fail.
  • RAID 1 and RAID 10 configurations tolerate multiple drive failures if no failed drives are mirrored to one another.
  • RAID 5 configurations tolerate one drive failure.
  • RAID 50 configurations tolerate one failed drive in each parity group.
  • RAID 6 configurations tolerate two failed drives at a given time.
  • RAID 60 configurations tolerate two failed drives in each parity group.
  • RAID 1 (ADM) and RAID 10 (ADM) configurations.

Before replacing drives ensure that the array has a current valid backup.
Confirm that the replacement drive is of the same type as the degraded drive (either SAS or SATA and either hard drive or solid state drive) also that the replacement drive has a capacity equal to or larger than the capacity of the smallest drive in the array. The controller will immediately fails if a drive is introduced that has insufficient capacity.

Systems with External Data Storage.

Ensure that the server is the first unit to be powered down and the last unit to be powered up. Taking this precaution ensures that the system does not, erroneously, mark the drives as failed when the server is powered up.

Replacing HP RAID Hard Disk Drives.

The most common reason for replacing a drive is that it has failed. However, another reason is to enhance the storage capacity of the system.

In fault-tolerant configuration, hot-plug hard drives can be replaced when server is ON, but in case of a Non-hot-plug hard drive, it should be replaced when server is OFF.

For systems that support hot-pluggable drives, if user replace a failed drive that belongs to a fault-tolerant configuration while the system power is on, all drive activity in the array pauses for 1 or 2 seconds while the new drive is initializing. When the drive is ready, Data Recovery to the replacement drive begins automatically. For systems that support non-hot-pluggable drives, if you replace a drive belonging to a fault-tolerant configuration while the system power is off, a POST message appears when the system is next powered up. This message prompts user to press the F1 key to start automatic Data Recovery.

If user do not enable automatic data recovery, the logical volume remains in a ready-to-recover condition and the same POST message appears whenever the system is restarted. Automatic data recovery (rebuild) When user replace a drive in an array, the controller uses the fault-tolerance information on the remaining drives in the array to reconstruct the missing data (the data that was originally on the replaced drive) and then write the data to the replacement drive. This process is called automatic Data Recovery or Rebuild.

Fault Tolerance.

If fault tolerance is compromised, the controller cannot reconstruct the data, and the data is likely to be lost permanently without the services of a professional data recovery provider.

Time Required For A Rebuild.

The time required for a rebuild depends on several factors:

  • The priority that the rebuild is given over normal I/O operations (user can change the priority setting by using HP SSA/ACU).
  • The amount of I/O activity during the rebuild operation.
  • The average bandwidth capability (MBps) of the drives.
  • The availability of drive cache.
  • >The brand, model, and age of the drives.
  • The amount of unused capacity on the drives.
  • For RAID 5 and RAID 6, the number of drives in the array.
  • The strip size of the logical volume.
  • Firmware versions of the Smart Array Controller and Hard Disk Drive.

A System could be unprotected against hard disk drive failure for an extended period during rebuild and upgrade. When possible, perform rebuild during periods of low system utilisation.

Request a Call Back

3 + 5 = ?

HP RAID Server

HP ProLiant Server Failure

Our spare parts customer distribution data base server had two hard disks drop out at the same time. Datlabs emergency services worked overnight and had us up and running by the end of play the following day. Great service !.

David BrownLondon

Faulty Hard Drives

My company uses Datlabs to rescue data from faulty hard drives with excellent results.

David BrocklehurstCambridge